General Wall vent with a very discreet design. It is possible to wallpaper and paint over the front. The vent is equipped with strong condensation insulation, overventilation protection, storm shield (certain models) and filters. The storm shield prevents the loss of energy when affected by the wind. The flow is regulated at the front which has a mechanism for changing the opening angle. The front is opened at the upper edge and forces air upwards which provides a comfortable distribution pattern even with underfloor heating. The vent is also available in a number of noise-reducing versions.
Standard wall pipe For the complete finish the vent is supplied with a wall pipe and external grille. The wall pipe consists of two sleeve couplings and wall pipe. Two alternative wall pipe are available. One of them consists of a number of modular pipes that can be fitted by pushing them together. The other is a full length pipe. When using the full length pipe, the adapters are supplied with seals which provide a secure seal against the pipe. The internal vent part and external grille fit on the adapters with a snap-in bracket. Internal vent part The internal vent part has strong condensation insulation, filter, as well as a front that can be angled upward at the upper edge to set the flow. The filter is mounted in a filter cassette which is also equipped with a guard to protect against any water running in. The front has four opening positions for varying the flow. The distribution pattern has been carefully developed in order to suit underfloor heating systems, the vent releases the air upwards and to the sides. The intervention of indoor air is very effective; strongly cooled air reaches a comfortable temperature only a few decimeters from the fitting. Mounting The vent should be placed high up on the wall. If there is a radiator, you should try to position the vent above it. Positioning it like this utilises the convection current, achieving the best comfort. The vent works excellently with underfloor heating systems as it was designed for this. Maintenance To ensure good air quality and maintain airflow, the filter should be cleaned/replaced 1–2 times a year. The standard filter is washable, use a mild detergent. Replace pollen and Flimmer filters. The standard/pollenfilter is installed in a filter cassette behind the front which is easily removed by releasing the front from the lower brackets and then lifting it up. The filter cassette is pulled straight out from the vent chassis. The Flimmer filter replaces the filter holder and can not be combined with the stormshield. Accessories There is a complete range of accessories for the vent. |